Time-delay functions
Engine start: Prevents nuisance genset starts in the event of momentary power system variation or loss. Not included
in utility-to-utility systems.
Transfer normal to emergency: Allows genset to stabilize before application of load. Prevents power interruption if
normal source variation or loss is momentary. Allows staggered transfer of loads in multiple transfer switch systems.
Retransfer emergency to normal: Allows the utility to stabilize before retransfer of load. Prevents needless power
interruption if return of normal source is momentary. Allows staggered transfer of loads in multiple transfer switch
systems.
Engine stop: Maintains availability of the genset for immediate reconnection in the event that the normal source fails
shortly after retransfer. Allows gradual genset cool down by running unloaded. Not included in utility-to-utility systems.
Delayed (programmed) transition: Transfers load to neutral position, disconnected from sources, to allow inductive
load voltages to decay.
Fail to disconnect timer: Signals external device to disconnect either the genset or utility to prevent extended
operation in parallel with the utility.
User interfaces
Basic interface panel
LED indicators provide at-a-glance source and transfer
switch status for quick summary of system conditions.
Test and override buttons allow delays to be bypassed
for rapid system checkout.
Digital display (M018)
The digital display provides a convenient method for
monitoring load power conditions, adjusting transfer
switch parameters, monitoring PowerCommand network
status or reviewing transfer switch events. Password
protection limits access to adjustments to authorized
personnel. The digital display comes standard with the
Level 2 PowerCommand microprocessor control and is
optional with the level 1 control.
User interface options
Front panel security key (M017)
Front panel access can be locked out using this option.
Prevents unauthorized transfers or testing. Prevents
unauthorized adjustments via the digital display.
Analog bar graph meter (D009)
An LED bar graph display provides easy to read
indication for normal and emergency voltages and
frequencies, load currents, power factor, and kilowatts.
Green, amber, and red LEDs provide at-a-glance
indication of system acceptability. Available as an option
with the Level 2 PowerCommand microprocessor
control.
Control options
Relay signal module (M023)
Provides an adjustable transfer pre-signal time delay of 0
to 60 seconds to prevent interruption of power during
elevator operation. Relay outputs include: Source 1
Connected and Available, Source 2 Connected and
Available, Not in Auto, Test/Exercise Active, Failed to
Disconnect, Failed to Synchronize, Failed to
Transfer/Retransfer, and Transfer pre-signal (elevator
signal).
Loadshed (M007)
Removes the load from the emergency power source by
driving the transfer switch to the neutral position when
signaled remotely. Transfers load back to the emergency
source when the signal contacts open. Immediate
retransfer to the preferred source when it is re-
established.
PowerCommand network interface (M031)
Provides connection to the PowerCommand network.
LonWorks compatible for integration into customer
monitoring strategy.
Load power and load current monitoring (M022)
Measures load phase and neutral, current, power factor,
real power (kW) and apparent power (kVA). Warns of
excessive neutral current resulting from unbalanced or
nonlinear loads.
* Note: Some options may not be available on all models - consult factory for availability.