Sens NRG24-20 Spezifikationen Seite 28

  • Herunterladen
  • Zu meinen Handbüchern hinzufügen
  • Drucken
  • Seite
    / 79
  • Inhaltsverzeichnis
  • LESEZEICHEN
  • Bewertet. / 5. Basierend auf Kundenbewertungen
Seitenansicht 27
Our energy working for you.™
www.cumminspower.com
©2008|Cummins Power Generation Inc.|All rights reserved|Specifications subject to change without notice|Cummins Power Generation
and Cummins are registered trademarks of Cummins Inc. PowerCommand, InPower and “Our energy working for you.” are trademarks of
Cummins Power Generation. Other company, product, or service names may be trademarks or service marks of others.
S-1566b (4/08) Page 5 of 6
Output signals from the PowerCommand control
include:
- Configurable relay outputs: Control includes (2) relay
output contacts rated at 2 A. These outputs can be
configured to activate on any control warning or
shutdown fault as well as ready to load, not in auto,
common alarm, common warning and common
shutdown.
- Ready to load (generator set running) signal: Operates
when the generator set has reached 90% of rated
speed and voltage and latches until generator set is
switched to off or idle mode.
Communications connections include:
- PC tool interface: This RS-485 communication port
allows the control to communicate with a personal
computer running InPower or PowerCommand for
Windows
®
software.
- Modbus RS-485 port: Allows the control to
communicate with external devices such as PLCs
using Modbus protocol.
Note - An RS-232 or USB to RS-485 converter is
required for communication between PC and control.
- Networking: This RS-485 communication port allows
connection from the control to the other Cummins
Power Generation products.
Mechanical drawings
PowerCommand human
machine interface
HMI211
Description
This control system includes an intuitive operator
interface panel that allows for complete genset control as
well as system metering, fault annunciation, configuration
and diagnostics. The interface includes five generator
set status LED lamps with both internationally accepted
symbols and English text to comply with customer
needs. The interface also includes an LED backlit LCD
display with tactile feel soft-switches for easy operation
and screen navigation. It is configurable for units of
measurement and has adjustable screen contrast and
brightness.
The run/off/auto switch function is integrated into the
interface panel.
All data on the control can be viewed by scrolling
through screens with the navigation keys. The control
displays the current active fault and a time-ordered
history of the five previous faults.
Features
LED indicating lamps:
- remote start
- not in auto
- shutdown
- warning
- auto
- run
128 x 64 pixels graphic LED backlight LCD.
Four tactile feel membrane switches for LCD defined
operation. The functions of these switches are defined
dynamically on the LCD.
Two tactile feel membrane switches dedicated for off
and back.
Allows for complete genset control setup.
Certifications: Suitable for use on generator sets that
are designed, manufactured, tested and certified to
relevant UL, NFPA, ISO, IEC, Mil Std., CE and CSA
standards.